Processor and graphics card specifications are live

Diagnose

Fast, then slow. That is a curve, and a curve has a cause.

A machine that starts strong and fades has reached a limit. The test holds the load long enough to see which one, and says so.

Run the testHow we measureFree · no install · standard run 3 min

What the report tells you

Three figures, each with its reading.

When it fell

s

The point on the curve where throughput left its peak. Ten seconds in is consistent with a boost timer. Ninety seconds in is consistent with heat. A sensor tool confirms which.

How much

%

Decay after the boost ends and the machine settles; the early boost step is shown on its own. Small is design; large and sliding is a problem.

The cause

consistent with

Which of a power budget expiring, cooling falling behind, or another program on the cores the shape is consistent with, with a confidence and the noise floor stated. A sensor tool confirms which.

The diagnosis

The shape of the curve, read for your case.

  1. 01A single step down

    Consistent with a power budget expiring: a burst, then the sustained limit. Comparing on mains in performance mode, or a sensor tool, confirms it. Normal, and adjustable only in firmware or the vendor's power tool.

  2. 02A steady slide

    Consistent with cooling falling behind, every second under load losing a little more; a sensor tool confirms it. This is the one that responds to cleaning, paste and airflow.

  3. 03Erratic

    Consistent with another program on the cores. The report cannot see which; the operating system's task list can.

Every class comes with a stated confidence and the measurement’s own noise floor. How the shape is read

Where a browser stops

What it cannot tell you.

  • No temperature reading: the browser infers thermal behaviour from the curve and never reports degrees.
  • No name for the competing program: the report can see the cores are shared, not by what.
  • One run cannot tell a quietly shared core from a slower machine. The before/after comparison can.

Which run

Standard, 3 minutes.

The standard run's forty-five seconds catches a boost timer expiring and the start of a slide. If the curve is still falling at the end, run the deep test.

All three kinds are free. The choice is on the set-up screen.

Questions

Asked in these words.

Why is my computer fast at first and then slow?
The processor boosted, then hit a limit. If the limit was a power budget it stepped down once and held; if it was heat it slid gradually; if another program took the cores it became erratic. A sustained-load test shows which, because each has a different shape.
Is it thermal throttling?
A slide is consistent with it. A single clean step is consistent with a power limit rather than heat, which cooling does not change; comparing on mains in performance mode, or a sensor tool, confirms which. The report names the shape and states how confident it is given the noise in the measurement.
What should I try first?
For a slide: clean the fans and check airflow. For a step: check the power plan and the vendor's performance mode. For erratic: open the task list and look for what is using the processor. Then run again; the report compares the two runs.

Find out why. 3 minutes, in the tab you have open.